• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Eaton Enhances Series G circuit breakers

Source: Eaton
14 November, 2010
Eaton Enhances Series G circuit breakers
Eaton Enhances Series G circuit breakers
Enhancements include ground fault protection and non-fused current limiting breaker modules.

November 14, 2010 - Eaton expanded its circuit breaker capabilities to offer enhanced ground fault protection and non-fused current limiting breaker modules for the Series G circuit breakers. Equipped with a built-in sensor and ground fault relay, Eaton’s Earth Leakage Modules are designed to protect against equipment damage and increase personnel safety by limiting current. Additionally, the current limiting breaker modules are designed to meet the increasing capacity of electrical source, which provides increased fault currents. They provide advanced system protection during overloads and both low and high-level short circuits. Eaton’s current limiter module provides automatic reset after interruption, unlike fused current limiters with a one-time use.

The molded case circuit breaker can be reset to restore power to the system, without having to find replacement fuses. Eaton manufactures non-fused current limiting modules in combination with Series G E-Frame breakers with interrupting capacities up to 150 kiloamperes (kA) at 480 Volts alternating current (Vac). The Series G current limiter module uses the stationary and moving contact arm design, creating a second set of contacts to assist during high fault interruption. During interruption, the second contacts open at the same time the main breaker contacts open, and the breaker trips to clear the fault. The current limiter module automatically resets after interruption.

Eaton’s Earth Leakage Module is designed to limit the current returning along an unintended path toward the source. The unintended current path can cause damage to sensitive machine control or risk personnel injury, if the current exceeds 30 milliamperes (mA). Offering superior Class 1 ground fault protection and improved ground fault coordination capabilities, Eaton’s Earth Leakage modules allow for protection sensitivities down to the 30 mA level and can be field installed.

Trending Articles

Advertisement

Related Industry Products

View all Industry Products
Advertisement
Advertisement