• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

Float Level Transmitters

Source: Pune Techtrol Pvt Ltd
24 October, 2013
Applications : Storage Tanks for Oil, Fuel, Chemicals, Pure / Industrial Water, Critical Inventory, Pressurized Vessels, Interface Applications and Waste Water Treatment Plant, Tank Gauging System for Ships, Nitric Acid, 98% H2SO4, 33% HCL, Diesel, Water, Mineral / Lube Oil, Solvents

Measuring range : upto 4000mm

Resolution : Standard ±12 mm, High ±6 mm

Enclosure : Cast Al w proof to IP 66 or Ex proof to Gr IIA & IIB or IIC

MOC : SS304, SS316 or PP, SS304 PVDF coating

Float : Ø60, Ø75 & Ø90

Process connections : 2-½" or 3" or 4" NB flanged to BS (option ANSI or

DIN std) or Triclover flange (sanitary applications)

Output : DC 4-20 mA (isolated) or 1 to 5 VDC or 4-20mA (HART) or RS485

Wiring system : 2 wire

Max load : 400 ohms

Max temperature : 80°C (PP) / 100°C (metallic MOC), 150°C (optional)

Max test pressure : 3 Kg/cm² (PP) / 10Kg/cm² (metallic MOC) 25 Kg/cm² (optional)