• ISA provides technical resources and standards to help industrial automation professionals advance their careers and the field. We enable automation professionals worldwide to solve problems and enhance their skills by bringing people together to create new technologies and share best practices with future automation professionals.
    • Industry Insights

  • We attract over 140,000 unique automation professionals monthly, making us the premier online content provider and the only dedicated electronic magazine in the automation industry.

    Monthly Magazine

    Back
    Back
  • M logo for Automation.com Monthly. Link to current issue.

NK Technologies upgrades ASXP Current Sensing Switch

Source: NK Technologies
05 September, 2012
NK Technologies upgrades ASXP Current Sensing Switch
NK Technologies upgrades ASXP Current Sensing Switch
Switch is now available with a user-adjustable setpoint from 1-80A and a relay output to control NEMA size 1 contactor coils and other inductive loads.

September 5, 2012 - NK Technologies’ ASXP Current Sensing Switch is now available with a user-adjustable setpoint from 1-80A. For use with 24VAC/DC or 120VAC supplies, these switches deliver OEM-caliber accuracy, precision tolerances, low hysteresis and an operation range between 40 and 100 hertz – functionality ideal for monitoring single and three-phase motors. They come standard with a robust solid-core enclosure and LED indicators for trip point contact status. The compact ASXP is a highly versatile option for single and three-phase motor monitoring, with a relay output that allows the sensor to be used to control NEMA size 1 contactor coils and other inductive loads.

A fixed two-second delay trip timer eliminates nuisance alarms due to start-up inrush or temporary over-current conditions in motor or heater status applications, eliminating the need for a separate time delay relay. After startup a second 0–20 second delay can be set to meet the needs of specific application requirements. In motor protection applications these sensors provide electronic proof-of-operation and detect current draw changes in the motor caused by pumps running dry or impending bearing failure. The ASXP is less expensive to install and serves as a non-intrusive alternative to differential pressure flow sensors or thermal switches. They also deliver quicker response times than Class 10 overload relays.

Users will also benefit from repeatable performance, constant hysteresis and linear response.